Update from 7.14 to 7.15

This document guides you through the update from Camunda BPM 7.14.x to 7.15.0. It covers these use cases:

  1. For administrators and developers: Database Updates
  2. For administrators and developers: Full Distribution Update
  3. For administrators: Standalone Web Application
  4. For developers: Exception Handling in Task API

This guide covers mandatory migration steps as well as optional considerations for the initial configuration of new functionality included in Camunda BPM 7.15.

Database Updates

Every Camunda installation requires a database schema update.

Procedure

  1. Check for available database patch scripts for your database that are within the bounds of your update path. Locate the scripts at $DISTRIBUTION_PATH/sql/upgrade in the pre-packaged distribution (where $DISTRIBUTION_PATH is the path of an unpacked distribution) or in the Camunda Nexus. We highly recommend executing these patches before updating. Execute them in ascending order by version number. The naming pattern is $DATABASENAME_engine_7.14_patch_?.sql.

  2. Execute the corresponding update scripts named

    • $DATABASENAME_engine_7.14_to_7.15.sql

    The scripts update the database from one minor version to the next, and change the underlying database structure. So make sure to backup your database in case there are any failures during the update process.

  3. We highly recommend to also check for any existing patch scripts for your database that are within the bounds of the new minor version you are updating to. Execute them in ascending order by version number. Attention: This step is only relevant when you are using an enterprise version of the Camunda BPM platform, e.g., 7.15.X where X > 0. The procedure is the same as in step 1, only for the new minor version.

Full Distribution

This section is applicable if you installed the Full Distribution with a shared process engine.

The following steps are required:

  1. Update the Camunda libraries and applications inside the application server
  2. Migrate custom process applications

Before starting, make sure that you have downloaded the Camunda BPM 7.15 distribution for the application server you use. It contains the SQL scripts and libraries required for the update. This guide assumes you have unpacked the distribution to a path named $DISTRIBUTION_PATH.

Camunda Libraries and Applications

Please choose the application server you are working with from the following list:

Custom Process Applications

For every process application, the Camunda dependencies should be updated to the new version. Which dependencies you have is application- and server-specific. Typically, the dependencies consist of any of the following:

  • camunda-engine-spring
  • camunda-engine-cdi
  • camunda-ejb-client

There are no new mandatory dependencies for process applications.

Standalone Web Application

If the standalone web application is in use, the current war artifact must be replaced by its new version.

If a database other than the default H2 database is used, the following steps must be taken:

  1. Undeploy the current version of the standalone web application
  2. Update the database to the new schema as described in the database update section
  3. Reconfigure the database as described in the installation section
  4. Deploy the new and configured standalone web application to the server

Exception Handling in Task API

With this release, the implementation of TaskService#handleBpmnError now throws a NotFoundException instead of a NullValueException in case no task with the given id exists. If the provided task id or error code were null or empty, a BadUserRequestException is thrown. Code that consumes this API might need to adapt its error handling. For more information about the reporting Bpmn Error in Task, please check the User Task documentation.

On this Page: